SPN 3719 – Soot Level High / DPF Soot Load High (Full 2025 Fix Guide)

SPN 3719 – Soot Level High / DPF Soot Load High (Full 2025 Fix Guide)

When your truck throws SPN 3719, it means the ECM believes the DPF is overloaded with soot.
This is a high-severity fault that must be fixed ASAP or the truck will:

  • Trigger constant regens

  • Lose power

  • Start derating

  • Hit 5 MPH derate

  • Damage the DPF, turbo, EGR, and SCR

The good news: Most SPN 3719 issues are fixable at home with the right diagnostics.


🚨 What Does SPN 3719 Actually Mean?

SPN 3719 = DPF Soot Load High
It tells you the ECM sees soot accumulation beyond safe limits.

This code appears on:

  • Cummins ISX / X15 / ISB

  • Detroit DD13 / DD15 / DD16

  • Paccar MX-13

  • Volvo / Mack

  • International A26

  • Duramax / Powerstroke

  • Ram 6.7 / Medium Duty trucks

When soot load is too high → the ECM blocks regen until the underlying issue is fixed.


⚠️ Symptoms of SPN 3719

  • Frequent regens

  • Parked regen required

  • Regen won’t start

  • Regen starts but NEVER finishes

  • High fan speed

  • Poor fuel economy

  • “Service Exhaust System”

  • Loss of power

  • High EGT temps

  • DEF light & MIL light

  • Truck enters derate

If soot % rises rapidly → you likely have a sensor or airflow issue.


🔍 What Causes SPN 3719? (Real Reasons Most People Don’t Know)

Here are the real causes in order of likelihood:


1. Regen Could Not Complete (Most Common)

If regen is interrupted or aborted:

  • Soot load rises

  • ECM locks regen

  • SPN 3719 appears


2. Bad DPF Differential Pressure Sensor

If the delta-P sensor reads incorrectly, the ECM thinks the DPF is full even if it’s not.

Common causes:

  • Sensor plugged

  • Water in pressure tubes

  • Cracked pressure lines

This is responsible for 40%+ of SPN 3719 cases.


3. Bad EGT (Exhaust Temp) Sensors

Regen requires 900–1,200°F.

If the ECM can’t read temp → regen is blocked.


4. Failed or Blocked EGR Valve

A stuck-open EGR valve floods the intake with exhaust → soot skyrockets.


5. Low Turbo Boost / Turbo Actuator Issue

If the turbo cannot build boost → exhaust temps stay too low for regen.


6. DEF / SCR Issues (Indirect Cause)

If SCR isn’t ready, regen is blocked.

Common causes:

  • NOx sensor faults

  • DEF dosing issues

  • P207F “DEF quality poor”


7. Airflow Problems (MAP, MAF, Charge Air)

Low intake airflow = low regen temperature.


8. True DPF Overloading

If truck has been idling excessively or regens blocked for too long, the DPF may actually be full.


What NOT to Do When You See SPN 3719

❌ Don’t clear the code

It WILL come back instantly.

❌ Don’t replace the DPF immediately

90% of cases do NOT require DPF replacement.

❌ Don’t attempt regen with a handheld scanner

Generic tools cannot run a REAL regen.

❌ Don’t keep driving

You risk hitting full 5 MPH derate.


🛠️ How to Fix SPN 3719 (Dealer-Level Procedure)

You'll need diesel software:

  • JPRO

  • Diesel Tech

  • Cummins Insite

  • Detroit DDDL

  • Paccar Davie

  • Volvo Tech Tool

These show soot %, pressure, temps, and allow forced regen.


STEP 1 — Check Soot Level on Diagnostic Software

Soot too high?

  • 100% = regen required

  • 120% = regen blocked

  • 150% = service regen only

  • 200% = DPF may need cleaning


STEP 2 — Check DPF Differential Pressure Readings

Idle pressure should be:

👉 0.2–0.8 PSI
If pressure is way higher → sensor or tube blockage.

If pressure is too low → sensor failed.


STEP 3 — Check EGT Sensor Health

Look for:

  • Frozen readings

  • Stuck values

  • Slow response

Bad sensors = regen blocked.


STEP 4 — Run VGT Turbo and Actuator Tests

Regen requires heat.
If turbo won’t close vanes → no regen.


STEP 5 — Test the DEF System

Check:

  • DEF pump pressure

  • Doser operation

  • NOx inlet/outlet readings

SCR faults often block regen.


STEP 6 — Repair the Root Cause

Most common fixes:

  • Replace DPF pressure sensor

  • Clean/replace EGT sensors

  • Clean DEF doser

  • Replace NOx sensor

  • Repair boost leak

  • Fix turbo actuator

  • Repair EGR valve stuck open


STEP 7 — Perform Required Aftertreatment Resets

Critical resets:

  • DPF differential pressure reset

  • Aftertreatment reset

  • Soot accumulator reset

  • NOx reset

  • DEF system reset

  • Turbo/VGT reset

Skipping this step = code returns.


STEP 8 — Perform a Forced Regen

A complete forced regen will:

  • Burn off soot

  • Validate the fix

  • Reset soot model

  • Restore full power


💻 Tools You Need to Fix SPN 3719 Properly

You MUST have:

✔ Diesel diagnostic laptop

✔ Nexiq USB-Link 3

✔ Software with aftertreatment controls

✔ Ability to run forced regen

DieselScanners kits include all:

  • Soot % monitoring

  • DPF pressure graphing

  • Aftertreatment resets

  • Forced regen

  • VGT turbo testing

  • Lifetime support

📞 Need help selecting your kit? Call Us: (800) 987-4850


💲 Why Fixing SPN 3719 Yourself Saves Thousands

Dealerships charge:

Service Cost
DPF diagnostic $300–$500
DPF pressure sensor $200–$450
EGT sensors $150–$400 each
DPF cleaning $600–$900
Forced regen $150–$300
Towing (if derated) $300–$1200

Your diesel laptop kit:

👉 Fixes soot load & regen issues
👉 Avoids derate
👉 Works on all future problems
👉 Pays for itself in 1–2 uses


🚛 Fix SPN 3719 Before It Causes Full Derate

SPN 3719 is a last warning before:

  • Complete regen failure

  • Turbo overheating

  • DPF cracking

  • Scr catalyst failure

  • 5 MPH derate

Fix it now with DieselScanners.